Thermostatic valve with increased flow capacity type RA-G

Thermostatic valve with increased flow capacity, type RA-G, is intended for use in pumped one-pipe water heating systems. They can also be used in two-tube gravity systems.
Thermostatic valves type RA-G have fixed flow rates.
All thermostatic valves type RA-G can be used with any thermo-static elements of the RA, RAW, RAX series or thermoelectric actuators TWA-A. For identification purposes, type RA-G valves are supplied with gray protective caps.
The cap should not be used to shut off the controlled medium. For these purposes, you should use a special metal
handle (code number 013G3300).
The push rod in the packing is made of chrome plated steel and does not require lubrication for the entire life of the valve.
All thermostatic valves type RA-G can be used with the entire range of compression fittings for copper pipes (information
about fittings on request). To prevent deposits and corrosion, RA-G valves should be used in hot water heating systems, where the coolant meets the requirements of the Rules for the Technical Operation of Power Plants and Heating Networks Russian Federation.

Nomenclature and technical characteristics

Type of Execution Connecting thread Throughput Kv 1), m 3 / h at relative range X p,
° C
Maximum pressure, bar Limiting pressure drop 2), bar Max. coolant temperature,
° C
Code number
With thermocouple Without
t / e
Working Test
entrance Output 0,5 1,0 1,5 2,0 -
RA-G 15 Angular int. R p ½ outdoor R p ½ 0,54 1,07 1,61 2,06 4,30 16 25 0,2 120 013G1676
Straight int. R p ½ outdoor R p ½ 0,51 0,94 1,35 1,63 2,30 013G1675
RA-G 20 Angular int. R p ¾ outdoor R p ¾ 0,57 1,11 1,16 2,20 5,01 013G1678
Straight int. R p ¾ outdoor R p ¾ 0,54 1,07 1,61 2,06 3,81 0,16 013G1677
RA-G 25 Angular int. R p 1 outdoor R p 1 0,59 1,27 1,77 2,41 5,50 013G1680
Straight int. R p 1 outdoor R p 1 0,57 1,16 1,71 2,27 4,58 013G1679

Valve device


1. Gland packing
2. O-ring
3. Valve disc
4. Valve seat
5. Pressure pin
6. Return spring
7. Valve stem
8. Valve body
9. Union nut
10. Connection nipple


Device



Thermostatic elements of the RA 2000 series

Thermostatic elements of the RA 2000 series are automatic temperature control devices intended for completing radiator thermostats type RA. The radiator thermostat is a direct-acting proportional air temperature controller with a small proportional band, which is currently equipped with heating systems in buildings for various purposes.
Thermostat RA consists of two parts:
universal thermostatic element of the RA 2000 series;
control valve with pre-setting of the flow rate RA-N (for two-pipe heating systems) or RA-G (for one-pipe system).
The production program for thermostatic elements of the RA 2000 series includes:
RA 2994 and RA 2940 with built-in temperature sensor, frost protection of the heating system, temperature setting range 5–26 ° C, device for fixing and limiting the temperature setting. In contrast to RA 2990, the RA 2940 thermocouple additionally has the function of
providing 100% overlap of the thermostat valve;
RA 2992 - thermocouples with a remote sensor, frost protection of the heating system, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting;
RA 2920 - thermoelements with a casing that protects against unauthorized interference, a built-in sensor, frost protection, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting;
RA 2922 - thermoelements with a cover protecting against unauthorized interference, a remote sensor, protection
from freezing, with a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting.
RA 2992 and RA 2922 are equipped with a 2 m ultra-thin capillary tube inside the housing remote sensor connecting it to the working bellows of the thermostatic element. During installation, the tube is pulled to the required length. Series RA 5060/5070 - a number of remote control thermoelements with frost protection of the heating system, a temperature setting range of 8-28 ° C, a device
to fix and limit the temperature setting:
RA 5062 - with a capillary tube length of 2 m;
RA 5065 - with a capillary tube length of 5 m;
RA 5068 - with a capillary tube length of 8 m;
RA 5074 - with capillary tube length 2 + 2 m.
All thermostatic elements can be combined with any RA type control valves.
and precise fastening of the thermocouple to the valve. The protective cover of the RA 2920 and RA 2922 thermocouples prevents their unauthorized dismantling and readjustment by unauthorized persons. Specifications radiator thermostats type RA comply with European standards EN 215-1 and Russian GOST 30815-2002.

Nomenclature and code numbers for ordering
Thermostatic elements of the RA 2000 series

Type of Model Description Temperature setting range 2), ° С Capillary tube length, m Code number
RA 2994 With built-in sensor and frost protection for the heating system 5–26 - 013G2994
RA 2992 5–26 0–2 013G2992
RA 2940 With built-in sensor and 100% thermostat valve overlap function 3) 0–26 - 013G2940
RA 2920 With built-in sensor and protective cover 5–26 - 013G2920
RA 2922 The same, with the remote sensor 1) 5–26 0–2 013G2922
RA 5062 Remote control element 8–28 2 013G5062
RA 5065 Also 8–28 5 013G5065
RA 5068 Also 8–28 8 013G5068
RA 5074 The same, with the remote sensor 1) 8–28 2 + 2 013G5074
1) The remote sensor is supplied with a capillary tube fully wound inside the sensor box. When installing the sensor, unwind only the required part of the tube.
2) The temperature scale is calibrated for Xp = 2 ° C. This means that the valve closes completely when the room temperature exceeds the setting temperature by 2 ° C.
3) To seal off the valve when the system is operating under pressure and to dismantle the heater, use a brass
handle (part number 013G3300).

Optional accessories

Product, description Code number
Handle for RA thermostat valve, brass 013G3300
Pins for limiting the temperature setting RA 2990/92/40 (10 pcs.) 013G1246
Temperature limiting pins RA 2920/22 (30 pcs.) 013G1237
Clip to prevent unauthorized dismantling of the thermocouple RA 2990/92 (20 pcs.) 013G5245
Screws to prevent unauthorized dismantling of the RA 2920/22 thermocouple (50 pcs.) 013G1232
Cover for thermocouple adjustment scale RA 2920 and 2922 013G1672
Mounting and locking tool kit 013G1236
Adapter for mounting thermocouples RA 5062, 5065 and 5068 on RA valves 013G5191
Adapter for installation of thermocouples RA 5062, 5065 and 5068 on valves with M30 x 1.5 seat thread 013G5194

Device and principle of operation


Thermostatic element design with built-in and remote sensor
1 - tuning handle;
2 - working bellows;
3 - setting scale;
4 - tuning spring;
5 - stock;
6 - remote sensor;
7 - capillary tube

Thermostatic remote control device with built-in sensor
1 - tuning handle;
2 - working bellows;
3 - setting scale;
4 - valve drive;
5 - drive bellows;

7 - capillary tube

Thermostatic remote control element with a remote sensor

1 - tuning handle;
2 - working bellows;
3 - setting scale;
4 - valve drive;
5 - drive bellows;
6 - adapter for mounting the actuator on the valve;
7 - capillary tube;
8 - remote sensor

dimensions


  • Shut-off and shut-off and connecting fittings;
  • Quick shutdown of devices and drainage of the coolant (RLV series);
  • Models with nickel-plated and chrome-plated brass bodies;
  • Angular and straight execution;
  • Equipment for a two-pipe heating system.
The updated range of valves mod thermostatic heads. Valve type RA. Two types of valves: for one-pipe and two-pipe systems.

Thermostat control valves are subdivided into:

valves for a two-pipe pump heating system, type RA-N, of increased resistance with a device for adjusting their flow capacity for hydraulic balancing of the pipeline system;
valves of increased capacity type RA-G for pumping one-pipe or two-pipe gravitational heating system.

Control valves for radiator thermostats RA are classified into two types: RA-N(for two-pipe pump heating systems) and RA-G(for one-pipe pumping and two-pipe gravitational systems) 1). The RA-N valve is a valve of increased hydraulic resistance with preliminary installation setting of its maximum flow capacity. Valves are produced with nominal diameter from 10 to 25 mm, straight and angle, nickel-plated. Danfoss' range includes a modification of the DN = 15 mm RA-NCX valve with a chrome body, which is usually used in conjunction with RAX thermocouples in chrome or color. RA-NCX valves are rarely used and valves RA-N DN = 10 and 25 mm do not find practical application in Russia at all, therefore they are not presented in this manual. Angle horizontal and three-axis valves are used when it is necessary to use a thermostatic element with a built-in sensor and the pipelines supplying the heat carrier to the heater are laid from below. The Danfoss range also includes a RA-N DN = 15 mm valve with a pressure connection for a copper pipe ø15x1 mm, which is used in horizontal apartment heating systems. Technical information for RA-N valves DN = 10 and 25 mm , RA-NCX and RA-N DN = 15 mm for press connections are presented in catalog VD.53.P17.50 "Radiator thermo-regulators and pipe fittings for hot water heating systems". RA-N valves are supplied with a red protective cap.

The main advantage of Danfoss RA-N valves is convenience and accuracy of adjustment to the required hydraulic resistance (flow capacity). In valves from other manufacturers, the setting is the number of revolutions of the special tool from the closed position. In this case, it is impossible to determine the value of the setting visually without disturbing the existing position of the device. It will not be accurate either, since it is not clear how many revolutions, for example 3 or 3 ¼. The presence of a special tool complicates the adjustment work. Externally, the same valves from different companies have different fixed settings. During installation, builders often confuse them and in the future cannot establish the heating system. Some companies offer to make the setting not on the thermostat-regulator, but on the shut-off valve, changing the number of revolutions of its stem. This is inconvenient, as it leads to a rise in the cost of work and a decrease in the accuracy of adjustment.

The presetting device is a throttling cylinder associated with a rotary crown. The different positions of the crown and cylinder correspond to the specific flow rates of the thermostat valve. On the crown, numeric indices of the positions of the tuning element are indicated. The setting indices must be determined during the hydraulic calculation of the heating system and set against drilling on the valve body during installation and commissioning work. Tuning is done without the use of any tool. The adjusting device is hidden under the thermostatic element and, when it is blocked, becomes inaccessible for accidental readjustment. In case of possible clogging of the valve at low presetting values, it is enough to turn the adjusting crown to the "N" position (fully open), and the valve is flushed with water. After that, the setting returns to its original position. The presetting values ​​are clearly visible on the crown (it is easy to set up or check the correctness of the setting). Each valve has 14 fixed setpoints (settings 1 to 7, N and six intermediate positions).

RA-G - a valve of low hydraulic resistance without a device to limit its capacity. The valves are manufactured with a nominal diameter of 15 to 25 mm with a nickel-plated body. They can also be straight and angled. The manual does not include the RA-G valves DN = 25 mm, since they are not practically used in Russia. Technical information on them is presented in catalog VD.53.P17.50 "Radiator thermostats and pipe and wire fittings for hot water heating systems". The RA-G valves are supplied with a gray protective cap. The RA-N and RA-G dampers are connected to the heating devices using threaded shanks with a union nut, and with the pipeline through a coupling socket. If necessary, in heating systems, a special version of RA-N valves can be used - with an external connecting thread or with a fitting for a press connection with a copper pipe ø15x1 mm. Many Russian factories produce heating devices with built-in Danfoss thermostat valves. Among them are the Moscow plant Santekhprom, which produces a bimetallic radiator Santekhprom-BMN Auto and convectors with a casing of the Santekhprom Auto series; JSC "Mechanical Plant" (St. Petersburg) - steel panel radiator of the "Konrad-Thermo" type; plant "Radiator" (Kimry) - steel tubular radiator of the "RS" type, etc. Convectors and steel radiators are equipped with thermostat valves for both two-pipe and one-pipe heating systems. Other devices with built-in thermostats are intended for two-pipe systems only. Danfoss thermostat valves built into a heater are generally similar in design and hydraulic performance to the RA-N and RA-G stand-alone thermostat valves. Technical characteristics of Russian heating devices with thermostats are given in the passports of manufacturers heating equipment, in the relevant materials of Danfoss LLC, and also included in the database of the Danfoss S.O. program for calculating heating systems on personal computers.

The main advantage of Danfoss RA-G valves- high throughput (RA-G DN = 20 mm has Kv = 2.06 m3 / h at Xp = 2 ° C). This is important in one-pipe heating systems to achieve optimal values ​​of the coefficient of flow of the coolant from the riser to the heater. High flow capacity is obtained due to the large valve seat area and increased stroke (more than 30% when using a thermostatic element with gas condensate filling compared to liquid-filled thermostats). These valves are the only ones with such a capacity that have the European quality certificate EN215. This is due to their ability to tightly shut off the coolant flow through the heater when the room temperature rises by 2 ° C more than the calculated one. In addition, the valve presents a unique service capability: its seat and plug can be completely replaced on site if required (without dismantling the valve).

RA-N valve for two-pipe pump heating system; PN = 10 bar, Tmax. = 120 ° C, with internal thread

Valves for two-pipe heating system RA

RA-N valve intended for use in two-pipe pumping systems for hot water heating with copper or stainless steel pipelines. Special crimping tools are required to connect the valve fitting to the pipeline.

Type of

Code
room

Du, mm

Description

kvs, m 3 / h;
kv, m 3 / h

Price (EUR)

Sketch

Corner, nickel plated

0,90; 0,04–0,73

Straight, nickel plated

0,90; 0,04–0,73

0,90; 0,04–0,73

22,80

0,90; 0,04–0,73

22,80

0,90; 0,04–0,73

23,69

Corner, nickel plated

0,90; 0,04–0,73

21,18

Straight, nickel plated

0,90; 0,04–0,73

21,18

Angle, 3-axis version, right-hand version, nickel plated

0,90; 0,04–0,73

33,25

Angled, 3-axis version, left-hand version, nickel plated

0,90; 0,04–0,73

33,25

Right Angle UK Version Nickel Plated

0,90; 0,04–0,73

26,35

Corner, nickel plated

1,40; 0,10–1,04

Straight, nickel plated

1,40; 0,10–1,04

26,56

Right Angle UK Version Nickel Plated

1,00; 0,16–0,80

32,94

Corner, nickel plated

1,40; 0,10–1,04

47,79

Straight, nickel plated

1,40; 0,10–1,04

47,79

Corner, chrome-plated

0,90; 0,04–0,73

24,11

Straight, chrome plated

0,90; 0,04–0,73

24,11

Corner, 3-axis version, right-hand version, chrome-plated

0,90; 0,04–0,73

Angled, 3-axis version, left-hand version, chrome-plated

0,90; 0,04–0,73

RA-N valve for two-pipe pump heating system; PN = 10 bar, Tmax. = 120 ° С, for press connection with the pipeline. It is possible to use tools from Geberit Mapress, REMS, Rothenberger, SANHA, Viega

Type of

Code
room

Du, mm

Description

kvs, m 3 / h;
kv, m 3 / h

Price (EUR)

Sketch

Corner, nickel-plated, for press connection

0,90; 0,04–0,43

Straight, nickel-plated, for press connection

0,90; 0,04–0,43

Angle, UK version, nickel plated, for press connection

0,90; 0,04–0,73

27,11

RA-G valve for one-pipe pumping and two-pipe gravitational heating systems; PN = 10 bar, Tmax. = 120 ° C, with internal thread

Control valve RA-G has an increased throughput and is intended for use in pumping one-pipe water heating systems with closing sections (bypasses).

Type of

Code
room

Du, mm

Thermostat RA consists of two parts:

  • universal thermostatic element of the RA 2000 series - automatic temperature control devices;
  • control valve with pre-setting of the flow rate RA-N (for two-pipe heating systems) or RA-G (for one-pipe system).

The production program for thermostatic elements of the RA 2000 series includes:

  • RA 2994 and RA 2940 with built-in temperature sensor, frost protection of the heating system, temperature setting range 5–26 ° C, device for fixing and limiting the temperature setting. Unlike RA 2990, the RA 2940 thermocouple additionally has a function that ensures 100% overlap of the thermostat valve;
  • RA 2992 - thermoelements with a remote sensor, frost protection of the heating system, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting;
  • RA 2920 - thermoelements with a casing that protects against unauthorized interference, a built-in sensor, frost protection, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting;
  • RA 2922 - thermoelements with a cover that protects against unauthorized interference, a remote sensor, frost protection, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting.

RA 2992 and RA 2922 are equipped with an ultra-thin capillary tube 2 m long, which is located inside the housing of the remote sensor, connecting it to the working bellows of the thermostatic element. During the installation process, the tube is pulled to the required length.

RА 5060/5070 series - a range of remote control thermoelements with frost protection of the heating system, a temperature setting range of 8-28 ° C, a device for fixing and limiting the temperature setting:

  • RA 5062 - with a capillary tube length of 2 m;
  • RA 5065 - with a capillary tube length of 5 m;
  • RA 5068 - with a capillary tube length of 8 m;
  • RA 5074 - with capillary tube length 2 + 2 m.

All thermostatic elements can be combined with any RA type control valves.

The clip-on connection allows simple and precise fastening of the thermocouple to the valve.

The protective cover of the RA 2920 and RA 2922 thermocouples prevents unauthorized disassembly and adjustment by unauthorized persons.

Technical characteristics of RA type radiator thermostats comply with European standards EN 215-1 and Russian GOST 30815-2002.

Model Description

Temperature setting range 2), ° С

Capillary tube length, m

With built-in sensor and frost protection for the heating system

With built-in sensor and frost protection for the heating system, with external sensor 1)

With built-in sensor and 100% thermostat valve overlap function 3)

With built-in sensor and protective cover

With built-in sensor and protective cover, with external sensor 1)

Remote control element

Remote control element

Remote control element, with remote sensor 1)

1) The remote sensor is supplied with a capillary tube fully wound inside the sensor box. When installing the sensor, unwind only the required part of the tube.

2) The temperature scale is calibrated for Xp = 2 ° C. This means that the valve closes completely when the room temperature exceeds the setting temperature by 2 ° C.

3) A brass handle must be used to seal off the valve in a pressurized system and to dismantle the heater.

LLC "Promarmatura XXI century" offers the widest range of products from Danfoss

The range of products includes: | | | | | | |
Danfoss is the world's largest manufacturer of radiator thermostats. Over the years, Danfoss has sold more than 300 million radiator thermostats worldwide, saving one million liters of fuel every day and preventing tons of environmental damage. carbon dioxide, sulfur compounds and other harmful substances. Radiator thermostats pay for themselves in less than two years, and a standard life of more than 20 years is a great opportunity to save money and energy.

Danfoss radiator thermostats are manufactured with built-in and remote sensors for optimal performance; plus a wide range of valves and accessories make up the widest range of our products.

Thermostatic elements of the RA 2000 series

Thermostatic elements of the RA 2000 series are automatic temperature control devices intended for completing RA type radiator thermostats. The radiator thermostat is a direct-acting proportional air temperature controller with a small proportional band, which is currently used in heating systems of buildings for various purposes. Thermostat RA consists of two parts:

  • universal thermostatic element of the RA 2000 series;
  • control valve with pre-setting of the flow rate RA-N (for two-pipe heating systems) or RA-G (for one-pipe system). The production program for thermostatic elements of the RA 2000 series includes:
  • RA 2994 and RA 2940 with built-in temperature sensor, frost protection of the heating system, temperature setting range 5–26 ° C, device for fixing and limiting the temperature setting. Unlike RA 2990, the RA 2940 thermocouple additionally has a function that ensures 100% overlap of the thermostat valve;
  • RA 2992 - thermoelements with a remote sensor, frost protection of the heating system, a temperature setting range of 5–26 ° С, a device for fixing and limiting the temperature setting;
  • RA 2920 - thermoelements with a casing that protects against unauthorized interference, a built-in sensor, frost protection, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting;
  • RA 2922 - thermoelements with a cover that protects against unauthorized interference, a remote sensor, frost protection, a temperature setting range of 5–26 ° C, a device for fixing and limiting the temperature setting. RA 2992 and RA 2922 are equipped with an ultra-thin capillary tube 2 m long, which is located inside the housing of the remote sensor, connecting it to the working bellows of the thermostatic element. During the installation process, the tube is pulled to the required length. RА 5060/5070 series - a range of remote control thermoelements with frost protection of the heating system, a temperature setting range of 8-28 ° C, a device for fixing and limiting the temperature setting:
  • RA 5062 - with a capillary tube length of 2 m;
  • RA 5065 - with a capillary tube length of 5 m;
  • RA 5068 - with a capillary tube length of 8 m;
  • RA 5074 - with capillary tube length 2 + 2 m.

    All thermostatic elements can be combined with any RA type control valves. The clip-on connection allows simple and precise fastening of the thermocouple to the valve. The protective cover of the RA 2920 and RA 2922 thermocouples prevents unauthorized disassembly and adjustment by unauthorized persons. Technical characteristics of RA type radiator thermostats comply with European standards EN 215-1 and Russian GOST 30815-2002.

    Technical characteristics of thermostatic elements of the RA 2000 series

    The main device of the thermostatic element is a bellows, which provides proportional control. The thermocouple sensor senses changes in the ambient temperature. The bellows and the sensor are filled with a highly volatile liquid and its vapors. The calibrated pressure in the bellows corresponds to its charging temperature. This pressure is balanced by the compression force of the tuning spring. As the air temperature around the sensor rises, some of the liquid evaporates, and the vapor pressure in the bellows increases. In this case, the bellows increases in volume, moving the valve spool towards closing the hole for the coolant flow into the heater until an equilibrium is reached between the spring force and the vapor pressure. When the air temperature drops, the vapors condense, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening until the position at which the system is in equilibrium again. The vapor fill will always condense in the coldest part of the transmitter, usually the furthest from the valve body. Therefore, the radiator thermostat will always react to changes room temperature without feeling the temperature of the coolant in the supply pipeline. However, when the air around the valve is nevertheless heated by the heat given off by the pipeline, the sensor can register more high fever than indoors. Therefore, to exclude such influence, it is recommended to install thermostatic elements, as a rule, in a horizontal position. Otherwise, it is necessary to use thermocouples with a remote sensor.

    Selection of the type of thermostatic element

    Thermostatic elements with built-in sensor

    When choosing a thermostatic element, one should be guided by the rule: the sensor must always respond to the air temperature in the room.

    Thermostatic elements with a built-in sensor must always be positioned horizontally so that ambient air can circulate freely around the sensor. They should not be installed in a vertical position, as the thermal effect on the sensor from the valve body and the heating pipe will lead to incorrect operation of the thermostat.

    Thermostatic elements with external sensor

    Thermostatic elements with a remote sensor should be used if: o thermoelements are closed with a blind curtain; o heat flow from the heating system pipelines affects the built-in temperature sensor; o thermoelement is located in the draft zone; o vertical installation of the thermocouple is required. The remote sensor of the thermostatic element must be installed on a wall free from furniture and curtains or on a plinth under the heating device if there are no heating pipes there. When installing the sensor, the capillary tube should be pulled out to the required length (maximum 2 m) and fixed to the wall using the supplied brackets or a special gun.

    Thermostatic elements of the RAW series

    Thermostatic elements of the RAW series are automatic temperature control devices intended for completing RA type radiator thermostats. The radiator thermostat is a direct-acting proportional air temperature controller with a small proportional band, which is currently used in heating systems in buildings for various purposes. Thermostat type RA consists of two parts: a universal thermostatic element of the RAW series and a control valve with a pre-set flow rate RA-N (for two-pipe heating systems) or RA-G (for one-pipe system).

    The RAW thermostatic elements production program includes:

  • RAW 5010 - thermostatic element with built-in temperature sensor;
  • RAW 5012 - thermostatic element with a remote temperature sensor;
  • RAW 5110 is a thermostatic element with a built-in sensor and a device for 100% overlapping of the thermostat valve.

    Thermostatic elements of the RAW series are equipped with anti-freeze protection devices, fixing and limiting the temperature setting. The RAW 5012 is equipped with a 2 m ultra-thin capillary tube that is wound inside the sensor housing and connects the remote sensor to the thermostatic element. During installation, the pipe is pulled to the required length. The clip-on connection allows simple and precise fastening of the thermocouple to the valve.

    Technical characteristics of radiator thermostats with thermoelements of the RAW series comply with European standards EN 215-1 and Russian GOST 30815-2002.

    In order to prevent unauthorized dismantling, the thermocouple can be fixed to the valve using a special retainer (see Accessories).

    Technical characteristics of thermostatic elements of the RAW series

    The main device of the thermostatic element is a bellows, which provides proportional control. The thermocouple sensor senses changes in the ambient temperature. The bellows and the sensor are filled with a special temperature-sensitive liquid. The calibrated pressure in the bellows corresponds to its charging temperature. This pressure is balanced by the compression force of the tuning spring. As the air temperature around the sensor rises, the liquid expands and the pressure in the bellows increases. In this case, the bellows increases in volume, moving the valve spool towards the closure of the hole for the coolant flow into the heater until an equilibrium is reached between the spring force and the fluid pressure. When the air temperature drops, the liquid begins to compress, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to a position at which the system equilibrium is re-established. To exclude the influence of warm air from the heating pipe of the heater, it is recommended to install thermostatic elements, as a rule, in a horizontal position. Otherwise, it is necessary to use thermocouples with a remote sensor.

    Thermostatic elements of the RAW-K series

    Thermostatic elements RAW-K series- automatic temperature controllers with a small proportional band. RAW-K are intended for installation on thermostat valves from Heimeier, Oventrop or MNG, built into the structure of steel panel radiators such as Biasi, Delta, DiaNorm, Diatherm, Ferroli, Henrad, Kaimann, Kermi, Korado, Purmo, Radson, Superia, Stelrad, Veha, Zehnder-Completto Fix. Thermostatic element of the RAW-K series has a liquid sensor with a temperature setting range of 8-28 ° C and is equipped with a frost protection device for the heating system.

    Danfoss produces 3 modifications of RAW-K thermoelements:

  • RAW-K 5030 with built-in temperature sensor;
  • RAW-K 5032 with remote temperature sensor;
  • RAW-K 5130 with built-in sensor and 100% thermostat valve overlap device.

    RAW-K 5032 is equipped with an ultra-thin capillary tube 2 m long, which is wound inside the body of the remote sensor, connecting it to the working bellows of the thermostatic element. During installation, the tube is pulled to the required length. Thermostatic elements of the RAW-K series comply with European standards EN 215-1 and Russian GOST 30815-2002.

    Living eco electronic radiator thermostat

    The Living eco® electronic radiator thermostat is a programmable microprocessor-based regulator for maintaining the set air temperature, mainly in residential buildings served by a hot water heating system. The thermostat is designed to be installed on valves of radiator thermostats instead of traditional thermostatic elements.

    Living eco® has programs P0, P1 and P2 that allow you to adjust the room temperature at different times of the day.

    The P0 program maintains a constant air temperature throughout the day. In order to save energy, programs P1 and P2 can reduce the temperature in the room at certain periods of time, which makes it possible to adapt the operation of the heating system to the lifestyle of the people living in it.

    The Living eco® thermostat is supplied complete with adapters for installation on Danfoss thermostat valves, as well as most other manufacturers. Installing and setting up the Living eco® thermostat is straightforward, with only three buttons on its panel.

    The Living eco® thermostat is equipped with an open window function, which cuts off the supply of heating medium to the heater when the room temperature drops sharply, which reduces heat loss, thereby increasing the efficiency of the heating system.

    Main characteristics of the thermostat:

  • ensuring energy saving;
  • ease of installation;
  • ease of customization;
  • maintaining a comfortable temperature;
  • "open window" function;
  • valve testing function in summer;
  • PID control law, which ensures accurate temperature control;
  • adaptive adjustment of the time of reaching the operating mode after the temperature has dropped;
  • the ability to set different temperatures for weekends and weekdays, as well as up to three periods during the day;
  • long service life of one set of batteries (two years);
  • limiting function (min./max.) temperatures;
  • childproof lock;
  • a special regime of long absence, during which the premises are not operated for a long time;
  • frost protection function of the heating system;
  • backlit display;
  • autonomous food.

    Pre-installed programs

  • Program without automatic temperature reduction function - maintains a constant, randomly set temperature throughout the day. Energy saving program - reduces the temperature to 17 ° C at night (22.30-06.00). It is possible to change the energy saving program. Extended energy saving program - reduces the temperature to 17 ° C at night (22.30-06.00) and during the day on weekdays (08.00-16.00). The extended energy saving program can be changed.

    The long-term absence function allows you to reduce the temperature in a room when it is not in use. The absence period and temperature are freely adjustable by the consumer.

    The choice of programs and their setting are made in accordance with the instructions attached to the thermoelement.

    Thermoelectric actuators TWA series

    Thermoelectric mini-actuators of the TWA series are designed for two-position control of various control valves in heating and heating and cooling systems of local ventilation units.

    The actuator is equipped with a visual travel indicator that indicates whether the valve is closed or open.

    Depending on the version, TWA actuators can be used with Danfoss RA, RAV8 and VMT valves, as well as Heimeier, MNG and Oventrop valves with M 30 x 1.5 actuator mounting threads. If the actuator is used with other types of valves, the valve must be checked to ensure that the geometry is compatible and that it closes. The supply voltage of the actuator is 24 or 230 V. The valves can be normally closed in the absence of voltage (NC) and normally open (NO). In addition, the normally closed actuator with a 24 V supply voltage is supplied with a limit switch (NC / S).

    Presetting thermostat valves RA-N and RA-NCX DN = 15 mm (chrome-plated)

    Control valves RA-N and RA-NCX are intended for use in two-pipe pumping systems for hot water heating.

    RA-N is equipped with a built-in device for preliminary (editing) adjustment of its bandwidth within the following ranges:

  • Kv = 0.04-0.56 m3 / h - for valves DN = 10 mm;
  • Kv = 0.04-0.73 m3 / h - for valves DN = 15 mm;
  • Kv = 0.10-1.04 m3 / h - for valves DN = 20 and 25 mm.

    The RA-N and RA-NCX valves can be combined with all thermostatic elements of the RA, RAW and RAX series, as well as with the thermoelectric actuator TWA-A.

    To identify the RA-N and RA-NCX valves, their protective caps are colored red. The protective cap must not be used to shut off the heating medium flow through the heater. Therefore, the handle (code number 013G3300) must be used.

    Valve bodies are made of pure nickel plated brass (RA-N) or chrome plated (RA-NCX).

    The technical characteristics of RA-N and RA-NCX valves in combination with thermostatic elements of the RA, RAW and RAX series comply with European standards EN 215-1 and Russian GOST 30815-2002, and the size of the connecting thread - with HD 1215 (BS 6284 1984). All Danfoss radiator thermostats are manufactured in ISO 9000 (BS 5750) certified factories.

    To prevent deposits and corrosion, the valves of the RA-N and RA-NCX thermostats should be used in hot water heating systems where the coolant meets the requirements of the Rules for the Technical Operation of Power Plants and Networks of the Russian Federation. In other cases, Danfoss should be contacted. It is not recommended to use compositions containing petroleum products (mineral oils) for lubricating valve parts.

    Adjustment to the calculated value is easy and accurate without the use of special tools. To do this, perform the following operations:

  • remove the protective cap or thermostatic element;
  • raise the tuning ring;
  • turn the dial of the setting ring so that the desired value is opposite the set mark "o" located on the side of the valve outlet (factory setting "N");
  • release the tuning ring.

    The presetting can be made in the range from "1" to "7" at intervals of 0.5. In the "N" position, the valve is fully open. Avoid mounting on the dark area of ​​the scale.

    When the thermostatic element is installed, the presetting is hidden and thus protected from unauthorized changes.

    Presetting thermostat valve RA-N with press connection

    The RA-N valve is intended for use in two-pipe pumping systems for hot water heating with copper or stainless steel pipelines. Special crimping tools are required to connect the valve connector to the pipeline. Valve body by appearance and the technical characteristics are identical to the standard RA-N valves DN = 15 mm. RA-N can be used with any type of thermostatic elements of the RA or RAW series, as well as with special design thermostatic elements type RAX and thermoelectric actuator TWA-A.

    The RA-N control valve is equipped with a built-in device for preliminary (mounting) adjustment of its Kv capacity in the range from 0.04 to 0.73 m3 / h.

    The protective cap is colored red for identification of the valves. The cap should not be used to shut off the controlled medium. For this purpose, a special metal handle (code number 013G3300) must be used. The valve body is made of DZR nickel-plated brass and the pressure pin is made of stainless steel. The pin does not require lubrication for the entire life of the valve. The gland packing can be replaced without draining the piping system. RA-N should be used in hot water heating systems where the coolant meets the requirements of the Rules for the Technical Operation of Power Plants and Networks of the Russian Federation. In other cases, Danfoss should be contacted. It is not recommended to use compositions containing petroleum products (mineral oils) for lubricating valve parts.

    Thermostat valve with increased flow rate RA-G

    Thermostatic valve with increased throughput RA-G is intended for use, as a rule, in one-pipe water heating systems with pumped circulation of the coolant that meets the requirements of the Rules for the Technical Operation of Power Plants and Heating Networks of the Russian Federation. It is not recommended to use the valve if there are mineral oil impurities in the heating medium.

    The RA-G is equipped with a gland that can be replaced without draining the heating system. The packing pin is made of chrome plated steel and does not require lubrication for the entire life of the valve. All versions of RA-G valves can be combined with any thermostatic elements of the RA series.

    The RA-G valves are supplied with gray (for identification purposes) protective caps, which must not be used to shut off the heating medium flow. Therefore, a special metal service shut-off handle (code no. 013G3300) must be used.

    X-traTM thermostatic valve set for heated towel rails and design radiators.

    The X-tra ™ thermostatic kit is specially designed for heated towel rails. It consists of a thermostat valve, a thermostatic element and a shut-off valve with drainage function. The innovative self-sealing connection of the valves to the radiator is a one-half inch thread. Valves and thermocouple are available in white, chrome and steel versions, suitable for most heated towel rails. This set is the perfect ending for a heated towel rail. Attractive and compact design allows you to install the thermostat under the heated towel rail parallel to the wall, eliminating accidental knocks on it.

    The nomenclature includes two types of thermostats with different control principles:

    • RAX, which regulates the room temperature;
    • RTX, which detects and regulates the temperature of the water leaving the heated towel rail. Used on towel warmers and adjustable to 5-10 ° C above the room temperature, the RTX thermostat provides a constant temperature for drying towels.
    The thermostats have the same design except for the setting scale numbers: on RAX - Roman, on RTX - Arabic.

    The valve assembly is a body with a two-way self-sealing fitting, which has two O-rings: one for sealing the connection of the fitting to the heated towel rail, the other for sealing the connection of the fitting with the valve body. The socket head cap screw is used to seal the valve body to fitting. If the O-rings do not fit the towel rail fittings, traditional sealing material is used.

  • The main task of any heating system is to provide a comfortable air temperature in the room. This temperature can be different depending on the purpose of the room, but if its unchanged during the day is a prerequisite, then the thermostat becomes indispensable. structural element heater.
    The Danfoss radiator thermostat consists of two parts: a valve and a thermostatic element (thermal head). Inside the thermostatic element there is a thin sealed cylinder - a bellows filled with a liquid or gaseous thermosensitive working substance. As the temperature rises, the bellows stretches and moves the associated rod, which presses on the rod in the valve, and the valve reduces the flow of coolant into the radiator. When the temperature drops, the process is reversed. Thus, the thermal head is a control mechanism, and the valve is an executive one.

    Manufacturer: Danfoss (Denmark).

    Danfoss radiator thermostat valves

    Radiator thermostat valves are divided into:
    - valves for a two-pipe pump heating system ( type RA-N) increased resistance with a device for adjusting their throughput to perform hydraulic balancing of the pipeline system;
    - valves of increased throughput type RA-G for pumping one-pipe or two-pipe gravitational heating system.

    Danfoss valve bodies are made of brass. The connection allows easy and precise attachment of the thermostatic element to the control valve. To identify the RA-N valves, their protective caps are colored red and the RA-G valves are gray.

    Danfoss RA-G thermostat valves

    RA-G 15 Thermostat valve RA-G 15 for one-pipe or two-pipe system, by connection type - straight or angle, connection size - 1/2 "(DN 15).RUB 1,930
    RA-G 20 Thermostat valve RA-G 20 for one-pipe or two-pipe system, by connection type - straight or angle, connection size - 3/4 inch (DN 20).RUB 2,460
    RA-G 25 Thermostat valve RA-G 25 for one-pipe or two-pipe system, according to the type of connection - straight or angle, connection size - 1 inch (DN 25).RUB 3,100

    Danfoss RA-N thermostat valves

    RA-N 15 Valve thermostat RA-N 15 for a two-pipe system, according to the type of connection - straight or angled, connection size - 1/2 inch (DN 15).RUB 1,600
    RA-N 20 Thermostat valve RA-N 20 for a two-pipe system, by connection type - straight or angled, connection size - 3/4 inch (DN 20).RUB 2,000
    RA-N 25 Thermostat valve RA-N 25 for a two-pipe system, by the type of connection - straight or angle, connection size - 1 inch (DN 25).RUB 3,600

    The RA-G and RA-N series valves can be combined with the RA series.


    Thermostatic element and radiator valve

    The Danfoss thermostatic equipment set consists of a RA-G radiator valve (for a one-pipe or two-pipe heating system) or RA-N (for a two-pipe heating system) and a RA thermostatic element.
    The set is designed for automatic regulation of the room temperature.
    Easily installed on various types of heating devices in apartments with centralized one-pipe and two-pipe heating systems.

    RA 2994 / RA-G 15 straight Code 013G2164B
    Direct thermostat valve RA-G 15 for one-pipe or two-pipe systems, thermostat RA 2994.
    RUB 2,990
    RA 2994 / RA-G 15 corner Code 013G2163B
    Angle thermostat valve RA-G 15 for one-pipe or two-pipe system, thermostat RA 2994.
    RUB 2,990
    RA 2940 / RA-G 15 straight Article 013G2144
    Direct thermostat valve RA-G 15 for one-pipe or two-pipe systems, thermostat RA 2940.
    RUB 3,200
    RA 2940 / RA-G 15 corner Article 013G2143
    Angle thermostat valve RA-G 15 for one-pipe or two-pipe system, thermostat RA 2940.
    RUB 3,200
    RA 2994 / RA-G 20 straight Code 013G2166B
    Direct thermostat valve RA-G 20 for one-pipe or two-pipe systems, thermostat RA 2994.
    RUB 3,390
    RA 2994 / RA-G 20 corner Code 013G2165B
    Angle thermostat valve RA-G 20 for one-pipe or two-pipe systems, thermostat RA 2994.
    RUB 3,390
    RA 2940 / RA-G 20 straight Article 013G2146
    Direct thermostat valve RA-G 20 for one-pipe or two-pipe systems, thermostat RA 2940.
    RUB 3,690
    RA 2940 / RA-G 20 corner Article 013G2145
    Angle thermostat valve RA-G 20 for one-pipe or two-pipe system, thermostat RA 2940.
    RUB 3,690
    RA 2940 / RA-N 15 straight Article 013G2154
    Direct thermostat valve RA-N 15 for two-pipe system, thermostat RA 2940.
    RUB 2,900
    RA 2940 / RA-N 15 corner Article 013G2153
    Angle thermostat valve RA-N 15 for two-pipe system, thermostat RA 2940.
    RUB 2,900
    RA 2940 / RA-N 20 straight Article 013G2156
    Direct thermostat valve RA-N 20 for two-pipe system, thermostat RA 2940.
    RUB 3,290
    RA 2940 / RA-N 20 corner Article 013G2155
    Angle thermostat valve RA-N 20 for two-pipe system, thermostat RA 2940.
    RUB 3,290

    Danfoss thermostatic elements

    Danfoss thermostatic elements (thermal heads) are automatic temperature control devices designed for completing radiator thermostats.
    The thermostat, equipped with a thermostatic element, maintains a constant temperature in the room at the desired level within the range from + 5 ° C to + 26 ° C with an accuracy of ± 1 ° C.
    It should be remembered that thermostats are for the most part regulatory fittings, but not shut-off(except for the RA2940 and RAW 5110 thermostats), therefore, if it is necessary to dismantle the radiator, the thermal head should be replaced with a bronze shut-off handle, which will completely shut off the coolant flow.

    Danfoss thermostatic elements

    RA 2994 Thermostatic element with gas-filled temperature sensor. Temperature adjustment range: from + 5 ° С to + 26 ° С.RUB 1,440
    RA 2992 Thermostatic element with gas-filled remote temperature sensor. Temperature adjustment range: from + 5 ° С to + 26 ° С. Capillary tube length: 2 m.RUB 2 200
    RA 2920 Thermostatic element with gas-filled temperature sensor and tamper-proof. Temperature adjustment range: from + 5 ° С to + 26 ° С.RUB 2 190
    RA 2940 Thermostatic element with gas-filled temperature sensor. Temperature adjustment range: from + 0 ° С to + 26 ° С. The ability to shut off the coolant supply.RUB 1,600
    RAW 5010 Thermostatic element with liquid temperature sensor. Temperature adjustment range: from + 8 ° С to + 28 ° С.RUB 1,390
    RAW-K Thermostatic element with liquid temperature sensor. Temperature adjustment range: from + 8 ° С to + 28 ° С.
    For installation on built-in valves (M30x1.5) of radiators with a lower connection - Rifar, Copa, Kermi, Demrad, Stelrad, Purmo, Korado.
    RUB 1,390
    Thermostatic remote control element with liquid temperature sensor. Temperature adjustment range: from + 8 ° С to + 28 ° С. Capillary tube length: 2 m (RA 5062), 5 m (RA 5065).

    RUB 4,590

    RUB 4,960

    When installing thermostats, it should be remembered that the effect of their use will be noticeable if they control radiators with low thermal inertia. Practically, these are all known types of modern radiators except cast iron. The latter, due to the large mass of cast iron and water, will heat up and cool down very slowly, negating the effect of regulation.

    Shut-off and connecting valves RLV are designed for lateral connection to the radiator of pipelines of a two-pipe heating system. Available in straight and angled versions.
    P y = 10 bar *; T max = 120 ° C; ΔP max = 0.6 bar.

    * Conditional pressure. See GOST 356-80 Pipeline fittings and details. Nominal, test and working pressures.