Danfoss is the world's largest manufacturer of radiator thermostators. Over the years, Danfoss sold more than 300 million radiator thermostators around the world, which saves a million fuel liters daily and prevent harm inflicted with tons carbon dioxide, sulfur compounds and other harmful substances. Radiator thermostators pay off in less than two years, and the standard service life of more than 20 years is a great opportunity to save money and energy.
Danfoss radiator thermostators are manufactured with embedded and remote sensors to ensure optimal functioning; Plus a wide range of valves and additional equipment make up the widest range of our products.
Thermostatic elements of the RA 2000 series
Thermostatic elements RA 2000 series - automatic temperature control devices designed to complete the RA radiator thermostators. Radiator thermostat is a proportional direct-acting air temperature controller with a small proportionality zone, which are currently equipped with building heating systems various destination. The thermostat Ra consists of two parts:
All thermostatic elements can be combined with any regulating valves of type RA. Clip connection provides simple and accurate mounting of the thermoelement on the valve. The protective cover of thermoelements RA 2920 and RA 2922 prevents their unauthorized dismantling and reconfiguration to unauthorized persons. Specifications Radiator thermostators type RA correspond to European standards EN 215-1 and Russian GOST 30815-2002.
Specifications of thermostatic elements of the RA 2000 series
The main device of the thermostatic element is a bellows that provides proportional regulation. The thermoelement sensor perceives the change in the ambient temperature. The bellows and the sensor are filled with an easy-to-sleep liquidity and its pairs. The adjusted pressure in the bellows corresponds to the temperature of its charging. This pressure is balanced by the power of the tuning springs. With increasing air temperature around the sensor, part of the fluid evaporates, and the pressure of vapors in the bellows grows. In this case, the bellows increase in the volume by moving the valve spool towards the closing of the hole for the coolant duct into the heater until the balance between the spring force and the vapor pressure is reached. When the air temperature decreases, the pairs are condensed, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to the position in which the equilibrium of the system will again be established. Steam filling will always be condensed in the coldest part of the sensor, usually most remote from the valve body. Therefore, the radiator thermostat will always respond to changes. room temperature, not feeling the temperature of the coolant in the underwear pipeline. However, when the air around the valve is still heated by heat, given by the pipeline, the sensor can register a higher temperature than indoors. Therefore, it is recommended to establish thermostatic elements to eliminate this influence, as a rule, in a horizontal position. Otherwise, it is necessary to apply thermoelements with a remote sensor.
Select the type of thermostatic element
Thermostatic elements with built-in sensor
When choosing a thermostatic element, it should be guided by the rule: the sensor should always react to the air temperature in the room.
Thermostatic elements with a built-in sensor should always be arranged horizontally so that the ambient air can freely circulate around the sensor. Do not install them in a vertical position, since the thermal effect on the sensor from the valve body and the heating system pipe will lead to the incorrect functioning of the thermostat.
Thermostatic elements with a remote sensor
Thermostatic elements with a remote sensor should be applied if: o Thermal elements are closed with a deaf curtain; o The heat flux from the heating system pipelines affects the built-in temperature sensor; o The thermoelement is located in the draft area; o required vertical installation of thermoelement. The remote sensor of the thermostatic element must be installed on the furniture-free and curtains or on a plinth under the heating device if there are no pipelines of the heating system. When installing the sensor, the capillary tube should be pulled out to the required length (maximum of 2 m) and fasten it on the wall using the accompanying brackets or a special pistol.
Thermostatic elements of the RAW series
Thermostatic elements raw Series - automatic temperature control devices designed to complete the RA radiator thermostators. Radiator thermostat is a proportional direct-acting air temperature regulator with a small proportionality zone, which is currently equipped with systems for the heating of buildings of various purposes. The RA type thermostat consists of two parts: a universal thermostatic element of the RAW series and an adjusting valve with a pre-adjustment of the RA-N bandwidth (for two-pipe heating systems) or Ra-G (for a single-tube system).
The program of the production of thermostatic elements of the RAW series includes:
The thermostatic elements of the RAW series are equipped with system protection devices from freezing, fixing and restricting the temperature setting. RAW 5012 is equipped with an ultra-thin capillary tube with a length of 2 m, which is swept inside the sensor housing and connects a remote sensor with a thermostatic element. In the process of installation, the pipe is pulled into the required length. Clip connection provides simple and accurate mounting of the thermoelement on the valve.
The technical characteristics of radiator thermostators with thermoelements of the RAW series correspond to European standards EN 215-1 and Russian GOST 30815-2002.
In order to prevent unauthorized dismantling, the thermoelement can be fixed on the valve using a special retainer (see additional accessories).
Specifications of thermostatic elements of the RAW series
The main device of the thermostatic element is a bellows that provides proportional regulation. The thermoelement sensor perceives the change in the ambient temperature. The bellows and the sensor are filled with a special heat sensitive liquid. The adjusted pressure in the bellows corresponds to the temperature of its charging. This pressure is balanced by the power of the tuning springs. When the air temperature is raised around the sensor, the liquid is expanding, and the pressure in the bellows grows. In this case, the bellows increase in the volume by moving the valve spool towards the closure of the heat carrier duct into the heating device until the equilibrium between the spring and the fluid pressure is reached. When the air temperature decreases, the liquid begins to shrink, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to the position in which the equilibrium of the system will again be established. To eliminate the effect of warm air from heating nozzle of the heating device, it is recommended to set thermostatic elements, as a rule, in a horizontal position. Otherwise, it is necessary to apply thermoelements with a remote sensor.
Thermostatically elements of the RAW-K series
Thermostatic elements of the RAW-K series are automatic temperature controllers with a small proportionality zone. RAW-K are designed to install on the thermostators of the thermostators of HEIMEIER, OVENTROP or MNG, built into the design of steel panel radiators type Biasi, Delta, Dianorm, Diatherm, Ferroli, Henerad, Kaimann, Kermi, Korado, Purmo, Radson, Superia, Stelrad, Veha, Zehnder-Completto Fix. The thermostatic element of the RAW-K series has a liquid sensor with a temperature setting range of 8-28 ° C and is equipped with a device for protecting the heating system from freezing.
The company "Danfoss" produces 3 modifications of the thermoelements of the RAW-K series:
RAW-K 5032 is equipped with an ultra-thin capillary tube with a length of 2 m, which is swept inside the exhaust sensor housing, connecting it with the thermostatic element working bellows. In the process of installation, the tube is pulled into the required length. The thermostatic elements of the RAW-K series comply with European standards EN 215-1 and Russian GOST 30815-2002.
Electronic radiator thermostat Living Eco
Electronic radiator thermostat Living ECO® is a programmable microprocessor regulator to maintain a predetermined air temperature, mainly in residential buildings serviced by water heating system. The thermostat is designed to be installed on the closens of radiator thermostators instead of traditional thermostatic elements.
In Living Eco®, the P0, P1 and P2 programs are installed, which allow you to adjust the temperature in the room at different periods of the day.
The P0 program supports constant air temperature throughout the day. P1 and P2 programs in order to save energy can reduce the temperature in the room during certain periods of time, which allows to adapt the operation of the heating system to the lifestyle of people living in it.
The Living ECO® thermostat is supplied with adapters for its installation on Danfoss thermostators, as well as most of other manufacturers. Installing and configuring the Living ECO® thermostat does not represent difficulties, there are only three buttons on its panel.
The Living ECO® thermostat is equipped with an open window function, which turns off the coolant supply to the heating device with a sharp decrease in the air temperature in the room, which reduces heat loss in the way increases the efficiency of the heating system.
The main characteristics of the thermostat:
Pre-installed programs
The function "Long absence" allows to reduce the temperature in the room when it is not operated. The absence period and temperature are adjusted arbitrarily by the consumer.
The selection of programs and their setup are made in accordance with the instructions attached to the thermoelement.
TWA thermoelectric actuators
The thermoelectric mini-actuators of the TWA series are designed for a two-position control of various control valves in heating systems and heat-drying of local ventilation plants.
The drive is equipped with a visual indicator of the stroke, which shows, in which position is the valve - closed or open.
TWA actuators depending on the modification can be used with valves of the RA, RAV8 and VMT series manufactured by Danfoss, as well as with HEIMEIER, MNG and OVENTROP valves, having a thread for fastening the drive M 30 x 1.5. In the case of applying a drive with other types of valve valve, the valve must be tested for compatibility of geometry and ensuring its closure. Power supply voltage - 24 or 230 V. Valves can be normally closed in the absence of voltage (NC) and normally open (NO). In addition, the normally closed drive with feed voltage 24 V is supplied with a limit switch (NC / S).
The thermostat valves with the pre-tuning RA-N and RA-NCX DU \u003d 15 mm (chrome)
RA-N and RA-NCX regulating valves are assigned to use in two-pipe water heating pumping systems.
RA-N is equipped with a built-in device for preliminary (mounting) adjusting its bandwidth within the following ranges:
Ra-n and Ra-NCX valves can be combined with all the thermostatic elements of the RA, RAW and RAX series, as well as with thermoelectric drive TWA-A.
To identify RA-N and RA-NCX valves, their protective caps are painted in red. The protective cap should not be used to overlap the coolant flow through the heating device. Therefore, the handle should be applied (code number 013G3300).
Valve housings are made of pure brass with nickel coating (Ra-N) or chrome (RA-NCX).
The technical characteristics of the RA-N and RA-NCX valves in combination with thermostatic elements of the RA, RAW and RAX series correspond to European standards EN 215-1 and Russian GOST 30815-2002, and the size of the connecting thread is the HD 1215 standard (BS 6284 1984). All radiator thermostators manufactured by Danfoss are manufactured at factories with ISO 9000 quality certificate (BS 5750).
To prevent deposits and corrosion valves of RA-N and RA-NCX thermostators should be used in water heating systems, where the coolant meets the requirements of the maintenance of electric stations and networks Russian Federation. In other cases, it is necessary to contact the company "Danfoss". It is not recommended to use compositions containing petroleum products (mineral oils) to lubricate the valve parts.
Setting on the calculated value is made easily and accurately without the use of special tools. To do this, make the following operations:
Pre-configuration can be performed in the range from "1" to "7" at intervals of 0.5. The "N" position valve is fully open. Installation should be avoided on a dark zone scale.
When the thermostatic element is mounted, the pre-tuning is hidden and, thus, protected from an unauthorized change.
The thermostat valve with a pre-tuning RA-N with a compound fitting
The RA-N valve is designed for use in two-pipe water heating pump systems with copper or stainless steel pipelines. To connect the valve with a pipeline with a pipeline, special crimping tools are required. Valve Case for appearance and the technical characteristics are identical to the standard valves Ra-N DN \u003d 15 mm. Ra-n can be used with any types of thermal static elements of the RA or RAW series, as well as with thermostatic elements of a special design of type RAX and thermoelectric TWA-A thermoelectric drive.
The RA-N control valve is equipped with a built-in device for preliminary (monkent) adjusting its KV bandwidth in the range from 0.04 to 0.73 m3 / h.
To identify valves, the protective cap is painted in red. The cap should not be used to overlap the adjustable medium. To this end, it is necessary to use a special metal handle (code number 013G3300). The valve body is made of nickel-plated brass DZR, and the pressure pin is made of stainless steel. The pin does not require lubrication over the entire life of the valve. The gland seal can be replaced without emptying the pipeline system. Ra-n should be used in water heating systems, where the coolant meets the requirements of the maintenance rules of electrical stations and networks of the Russian Federation. In other cases, it is necessary to contact the company "Danfoss". It is not recommended to use formulations containing oil products (mineral oils) to lubricate the valve parts.
The thermostat valve with increased bandwidth RA-G
The valve thermoregulating with increased bandwidth RA-G is designed for use, as a rule, in single-pipe systems of water heating with a pumping circulation of the coolant that meets the requirements of the technical operation of electric stations and thermal networks of the Russian Federation. The valve is not recommended to be used if impurities of mineral oil are present in the coolant.
RA-G is equipped with a seal that can be replaced without emptying the heating system. The pressure pin in the gland is made of chrome steel and does not require lubrication over the entire life of the valve. All performances of RA-G valves are combined with any thermostatic elements of the RA series.
Ra-G valves are supplied with gray (for identifying) protective caps that should not be used to overlap the coolant flow. Therefore, a special metal service locking handle should be applied (code number 013G3300).
A set of X-TRATM thermostatic reinforcement for heated towel rails and design radiators.
The thermostatic X-TRA ™ kit is specifically designed for heated towel rails. It consists of a thermostat valve, a thermostatic element and a shut-off valve with a drainage function. Innovative self-adhesive connection of valves to the radiator is carried out using a thread one second inches. Valves and thermoelement are available in white, chrome-plated and steel versions, suitable for most heated towel rails. This kit is the perfect ending of the heated towel rail. Attractive and compact design allows you to install the thermostat under the heated towel railway parallel to the wall, eliminating random strikes on it.
Nomenclature presents two types of thermostators with various principles of regulation:
- RAX, regulating the room air temperature;
- RTX, which determines and regulating the temperature of water at the outlet of the heated towel rail. Used on heated towel rails and customizable by 5-10 ° C over temperature indoors, the RTX thermostat provides a constant temperature for drying towels.
The valve assembly is a housing with a two-sided self-fitting fitting, which has two sealing rings: one - to compact fitting compound with a heated towel rail, second to seal fitting compound with valve body. The screw with an internal hexagon is used to ensure the sealing of the valve body compound with the fitting. If the sealing rings are not suitable for the fittings of the heated towel rail, the traditional sealing material is used.
Valve thermostatic with increased capacity RA-G
The valve thermostatic with increased bandwidth type RA-G is intended for use in pumping single-tube water heating systems. They can also be used in two-pipe gravitational systems.
The valves are thermostatic type RA-Gs have fixed bandwidth values.
All valves are thermostatic type Ra-Gs can be used with any thermo-static elements of the RA, RAW, RAX series or TWA-A thermoelectric drives. For identification, RA-G valves are supplied with gray protective caps.
The cap should not be used to overlap the adjustable medium. For these purposes should be used special metallic
Handle (code number 013g3300).
The pressure rod in the seal seal is made of chrome steel and does not require lubrication over the entire life of the valve.
All valves are thermostatic types of RA-G can be used with the entire list of compression fittings for copper pipes (information
About fittings on request). To prevent deposits and corrosion, RA-G valves should be used in water heating systems, where the coolant meets the requirements of the maintenance rules of electric stations and thermal networks of the Russian Federation.
Nomenclature and specifications
A type | Execution | Connecting thread | Bandwidth KV 1), m 3 / h at the relative range x p, ° S. |
Maximum pressure, bar | Limit pressure limit 2) bar | Max. Temperature of the germotel, ° S. |
Code number | ||||||
With thermoelement | Without T / E. |
Work | Testing | ||||||||||
entrance | Output | 0,5 | 1,0 | 1,5 | 2,0 | - | |||||||
RA-G 15 | Angular | Internal R P ½ | external. R P ½ | 0,54 | 1,07 | 1,61 | 2,06 | 4,30 | 16 | 25 | 0,2 | 120 | 013G1676. |
Straight | Internal R P ½ | external. R P ½ | 0,51 | 0,94 | 1,35 | 1,63 | 2,30 | 013G1675 | |||||
RA-G 20 | Angular | Internal R P ¾ | external. R P ¾ | 0,57 | 1,11 | 1,16 | 2,20 | 5,01 | 013G1678. | ||||
Straight | Internal R P ¾ | external. R P ¾ | 0,54 | 1,07 | 1,61 | 2,06 | 3,81 | 0,16 | 013G1677 | ||||
RA-G 25 | Angular | Internal R p 1. | external. R p 1. | 0,59 | 1,27 | 1,77 | 2,41 | 5,50 | 013G1680. | ||||
Straight | Internal R p 1. | external. R p 1. | 0,57 | 1,16 | 1,71 | 2,27 | 4,58 | 013G1679. |
Valve device
1. Slip seal
2. Ring seal
3. Plate of valve
4. Valve saddle
5. Purpose pin
6. Returnable spring
7. Stank Valpana
8. Valve housing
9. Caid Nut
10. Connecting Nippel
Device
Thermostatic elements of the RA 2000 series
Thermostatic elements of the RA 2000 series - automatic temperature control devices designed to complete the radiator thermostators such as RA.Diatoric thermostat is a proportional direct-acting air temperature controller with a small proportion zone, which is currently equipped with system heating systems for various purposes.
The thermostat Ra consists of two parts:
universal thermostatic element of the RA 2000 series;
Adjusting valve with pre-tuning bandwidth Ra-N (for two-pipe heating systems) or RA-G (for a single-tube system).
The program of production of thermostatic elements of the RA 2000 series includes:
RA 2994 and RA 2940 with a built-in temperature sensor, protection of the heating system from freezing, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting. In contrast to Ra 2990, the thermoelement Ra 2940 additionally has a function,
providing 100% overlap of the thermostat valve;
RA 2992 - Thermal elements with a remote sensor, protection of the heating system from freezing, a range of temperature setting 5-26 ° C, a device for fixing and is limited to a temperature setting;
RA 2920 - thermoelements with a casing that protects against unauthorized interference, built-in sensor, freezing protection, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting;
RA 2922 - thermoelements with a casing that protects against unauthorized intervention, remote sensor, protection
From freezing, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting.
Ra 2992 and Ra 2922 are equipped with an ultra-thin capillary tube with a length of 2 m, which is inside the body of the remote sensor, connecting it with the thermostatic element working bellows. During the installation, the tube is pulled out on the required length. Seria of RA 5060/5070 - a number of thermoelements of remote control with the protection of the heating system from freezing, the temperature setting range is 8-28 ° C, device
To fix and restrict temperature settings:
RA 5062 - with a length of the capillary tube 2 m;
RA 5065 - with a capillary tube length 5 m;
RA 5068 - with a capillary tube length of 8 m;
Ra 5074 - with a capillary tube 2 + 2 m.
All thermostatic elements can be combined with any regulating valves of the RA type. Cline compound provides easy
And the exact mounting of the thermoelement on the valve. The protection cover of thermoelements Ra 2920 and Ra 2922 prevents their unauthorized dismantling and reconfiguration by unauthorized persons. The technical characteristics of the radiator thermostators of the type RA correspond to European standards EN 215-1 and Russian GOST 30815-2002.
Nomenclature and code numbers for ordering
Thermostatic elements of the RA 2000 series
A type | Description of the model | Temperature setting range 2), ° С | The length of the capillary tube, m | Code number |
RA 2994. | With integrated sensor and protection of the heating system from freezing | 5–26 | - | 013G2994. |
RA 2992. | 5–26 | 0–2 | 013G2992. | |
RA 2940. | With built-in sensor and 100% overlap of thermostat valve 3) | 0–26 | - | 013G2940. |
RA 2920. | With built-in sensor and protective casing | 5–26 | - | 013G2920 |
RA 2922. | The same, with remote sensor 1) | 5–26 | 0–2 | 013G2922. |
RA 5062. | Element of remote control | 8–28 | 2 | 013G5062. |
RA 5065. | Also | 8–28 | 5 | 013G5065. |
RA 5068. | Also | 8–28 | 8 | 013G5068. |
RA 5074. | The same, with remote sensor 1) | 8–28 | 2 + 2 | 013G5074. |
2) The temperature scale is separated for xp \u003d 2 ° C. This means that the valve closes completely when the room temperature exceeds the setting temperature by 2 ° C.
3) for sealed overlap of the valve when the system running under pressure and dismantling the heating device must be used brass
Handle (Catalog code number 013G3300).
Extra accessories
Product, Description | Code number |
Handle for valve thermostat type RA, brass | 013G3300. |
Pins to limit the temperature setting RA 2990/92/40 (10 pcs.) | 013G1246. |
Pigs to limit the temperature setting Ra 2920/22 (30 pcs.) | 013G1237 |
Fixator to prevent unauthorized dismantling of thermoelement RA 2990/92 (20 pcs.) | 013G5245 |
Screws to prevent unauthorized dismantling of thermoelement RA 2920/22 (50 pcs.) | 013G1232. |
Cover for the RA 2920 and 2922 thermoelement setting | 013G1672. |
Set of tools for mounting and locking | 013G1236. |
Adapter for installation of thermoelements Ra 5062, 5065 and 5068 on valves type RA | 013G5191. |
Adapter for installing thermoelements Ra 5062, 5065 and 5068 on valves with m30 x 1.5 | 013G5194. |
Device and principle of operation
Device of the thermostatic element with built-in and remote sensor
1 - tuning handle;
2 - working bellows;
3 - wing settings;
4 - a tuning spring;
5 - rod;
6 - remote sensor;
7 - capillary tube
Device of the thermostatic element of remote control with the built-in sensor
1 - tuning handle;
2 - working bellows;
3 - wing settings;
4 - valve drive;
5 - Drive Sylph;
7 - capillary tube
Device thermostatic remote control element with remote sensor
1 - tuning handle;
2 - working bellows;
3 - settings;
4 - valve drive;
5 - Drive Sylph;
6 - adapter for installation of the drive on the valve;
7 - capillary tube;
8 - remote sensor
dimensions
The main task of any heating system is to provide a comfortable air temperature in the room. This temperature can be different depending on the purpose of the room, but if it is a prerequisite for its immutability during the day, the thermostat becomes an indispensable structural element of the heating device.
Radiator thermostat Danfoss. Consists of two parts: valve and thermostatic element (thermal heads). Inside the thermostatic element is a thin hermetic cylinder - a belliff filled with liquid or gaseous heat-sensitive working substance. When the temperature is raised, the bellows stretch and moves the rod associated with it, which presses on the rod in the valve, and the valve reduces the coolant flow into the radiator. When the temperature decreases, the process goes in reverse order. Thus, the thermal head is the control mechanism, and the valve is executive.
Manufacturer: Danfoss (Denmark).
Danfoss radiator thermostators valves
Valves of radiator thermostators are divided into:
- valves for a two-pipe pumping system of heating (type Ra-n) of increased resistance with the installation device of their bandwidth for performing hydraulic balancing of the pipeline system;
- Valves of increased bandwidth type Ra-G for pumping single-tube or two-pipe gravitational heating system.
Valve housings Danfoss are made of brass. The compound provides a simple and accurate mounting of the thermostatic element on the adjusting valve. To identify Ra-N valves, their protective caps are painted in red, and Ra-G is in gray.
Danfoss RA-G thermoregulators valves
RA-G 15 | The RA-G 15 thermostat valve for a single-tube or two-pipe system, by type of connection - direct or angular, connecting size is 1/2 inches (Du 15). | 1 930 rub. |
RA-G 20 | The RA-G 20 thermostat valve for a single-tube or two-pipe system, by type of connection - direct or angular, connecting size is 3/4 inches (Du 20). | 2 460 rub. |
RA-G 25 | RA-G 25 thermostat valve for a single-pipe or two-pipe system, by type of connection - direct or angular, connecting size is 1 inch (Du 25). | 3 100 rubles. |
Danfoss RA-N thermoregulators valves
RA-N 15 | The RA-N 15 thermostat valve for a two-pipe system, by type of connection - direct or angular, connecting size is 1/2 inches (Du 15). | 1 600 rub. |
RA-N 20 | The RA-N 20 thermostat valve for a two-pipe system, by type of connection - direct or angular, connecting size is 3/4 inches (Du 20). | 2 000 rubles. |
RA-N 25 | The valve of the RA-N 25 thermostat for a two-pipe system, by type of connection - direct or angular, connecting size is 1 inch (Du 25). | 3 600 rub. |
With the valves of the RA-G and RA-N series, you can combine the RA series.
Thermostatic element and radiator valve
Danfoss thermostatic equipment kit consists of radiator valve Ra-G (for a single-tube or two-pipe heating system) or Ra-N (for a two-pipe heating system) and the thermostatic element Ra.
The kit is intended for automatic control of air temperature in the room.
It is easy to install on various types of heating devices in a quarter area with a centralized single-tube and two-pipe heating system.
RA 2994 / RA-G 15 straight Article 013G2164B. The direct valve of the RA-G 15 thermostat for a single-tube or two-pipe system, the thermostat Ra 2994. | 2 990 rub. |
RA 2994 / RA-G 15 corner Article 013G2163B. The angle valve of the RA-G 15 thermostat for a single-tube or two-pipe system, the thermostat Ra 2994. | 2 990 rub. |
RA 2940 / RA-G 15 straight Article 013G2144. The direct valve of the thermostat Ra-G 15 for a single-pipe or two-pipe system, the thermostat Ra 2940. | 3 200 rubles. |
RA 2940 / RA-G 15 corner Article 013G2143. The angle valve of the RA-G 15 thermostat for a single-tube or two-pipe system, the thermostat Ra 2940. | 3 200 rubles. |
RA 2994 / RA-G 20 straight Article 013G2166B. The direct valve of the thermostat Ra-G 20 for a single-tube or two-pipe system, the thermostat Ra 2994. | 3 390 rub. |
RA 2994 / RA-G 20 corner Article 013G2165B. The angle valve of the RA-G 20 thermostat for a single-tube or two-pipe system, the thermostat Ra 2994. | 3 390 rub. |
RA 2940 / RA-G 20 straight Article 013G2146. Direct valve thermostat Ra-G 20 for a single-tube or two-pipe system, thermostat Ra 2940. | 3,690 rubles. |
RA 2940 / RA-G 20 corner Article 013g2145 Corner valve RA-G 20 thermostat for a single-tube or two-pipe system, thermostat Ra 2940. | 3,690 rubles. |
RA 2940 / RA-N 15 straight Article 013g2154 The direct valve of the RA-N 15 thermostat for a two-pipe system, the thermostat Ra 2940. | 2 900 rub. |
RA 2940 / RA-N 15 corner Article 013G2153. The angle valve of the thermostat Ra-N 15 for a two-pipe system, the thermostat Ra 2940. | 2 900 rub. |
RA 2940 / RA-N 20 straight Article 013G2156. Direct valve thermostat Ra-N 20 for a two-pipe system, thermostat Ra 2940. | 3 290 rubles. |
RA 2940 / RA-N 20 corner Article 013g2155 The angle valve of the RA-N 20 thermostat for a two-pipe system, the thermostat Ra 2940. | 3 290 rubles. |
Thermostatic elements of Danfoss.
Thermostatic elements (thermal heads) Danfoss are automatic temperature control devices intended for a complete set of radiator thermostators.
The thermostat equipped with a thermostatic element maintains a constant temperature in the room at the desired level in the range from + 5 ° C to + 26 ° C with an accuracy of ± 1 ° C.
It should be remembered that thermostators are mostly regulatory reinforcement but not shut-off (With the exception of the thermostats RA2940 and RAW 5110), so if you need to disassemble the radiator, the thermal head should be replaced with a bronze shut-off handle, which will ensure the complete overlap of the coolant flow.
Thermostatic elements of Danfoss.
RA 2994. | Thermostatic element with a gas-filled temperature sensor. Temperature adjustment range: from + 5 ° C to + 26 ° C. | 1 440 rub. | |
RA 2992. | Thermostatic element with a gas-filled remote temperature sensor. Temperature adjustment range: from + 5 ° C to + 26 ° C. The length of the Capillary Tube: 2 m. | 2 200 rubles. | |
RA 2920. | Thermostatic element with a gas-filled temperature sensor and protection against unauthorized intervention. Temperature adjustment range: from + 5 ° C to + 26 ° C. | 2 190 rubles. | |
RA 2940. | Thermostatic element with a gas-filled temperature sensor. Temperature adjustment range: from + 0 ° C to + 26 ° C. The possibility of overlapping the supply of the coolant. | 1 600 rub. | |
RAW 5010. | Thermostatic element with liquid temperature sensor. Temperature adjustment range: from + 8 ° C to + 28 ° C. | 1 390 rub. | |
RAW-K. | Thermostatic element with liquid temperature sensor. Temperature adjustment range: from + 8 ° C to + 28 ° C. To install on the built-in valves (M30X1.5) of the bottom liner - Rifar, Copa, Kermi, Demrad, Stelrad, Purmo, Korado. | 1 390 rub. | |
Thermostatic remote control member with liquid temperature sensor. Temperature adjustment range: from + 8 ° C to + 28 ° C. Length of the capillary tube: 2 m (Ra 5062), 5 m (RA 5065). | 4 590 rubles. 4 960 rubles. |
By installing thermostat, it should be remembered that the effect of their use will be tangible if they control radiators with low thermal inertia. Practically, these are all the well-known types of modern radiators besides cast iron. The latter, due to the large mass of the cast iron and the water will be heated and cool very slowly, reducing the control effect.
RLV shut-off and connecting valves are designed for lateral connection to the radiator of pipelines of a two-pipe heating system. We are produced in direct and corner execution.
P y \u003d 10 bar *; T max \u003d 120 ° C; ΔР Max \u003d 0.6 bar.
* Conditional pressure. See GOST 356-80 fittings and pipelines. Conditional pressure, trial and workers.
Firm Danfoss. Developed thermostatic elements of the RTR 7000 series - automatic temperature control devices designed to complete the RTR radiator thermostators. The radiator thermostat is a proportional direct-action air temperature regulator with a small proportion zone, which is currently equipped with systems for the heating of buildings of various purposes.
On the radiators of your apartment, two types of control valves, RTR-G or RTR-N can be installed, depending on the specific conditions: a two-pipe or single-tube heating system (help in choosing and installing RA thermostators on radiators in your home \u003e\u003e\u003e).
After installing radiator thermostators, there is no need to open windows to regulate the temperature in the rooms. Thermostators will maintain a constant temperature in the range from 5-26 ° C, at the desired level, with an accuracy of ± 1 ° C.
Radiator thermostators guarantee the necessary water distribution over the entire heating system. At the same time, even the most remote radiators will ensure the required heat supply in the room.
In more detail about Danfoss thermostators and their setup, you can read here \u003e\u003e\u003e
Thermostatic lemps for installation on the RTR-N, RTR-G valve (old RA series) and valves built into radiators:
Sketch |
Artkul |
Description |
T-Range Range, ºC |
Length of the capilalar tube, m |
Accession |
||
With a gas-filled integrated temperature sensor | |||||||
013G7091 | RTR 7000. |
RTR 7091 BIS, "0" |
With a gas-filled integrated temperature sensor, with the ability to set up 0ºC | ||||
With a gas-filled withdrawal temperature sensor | |||||||
RTR 7094 BIS, TemPerproof |
With a gas-filled integrated temperature sensor and a protective casing from unauthorized intervention |
||||||
With a gas-filled remote temperature sensor and protective casing from unauthorized intervention | |||||||
RTR 7095 BIS, RTD Service | |||||||
With built-in temperature sensor | |||||||
RTRW 7081 BIS, "0" |
With built-in temperature sensor, with the ability to set up 0 ° C | ||||||
013G7082. | With a remote temperature sensor | ||||||
Remote control, with a liquid built-in temperature sensor | |||||||
With a gas-filled integrated temperature sensor. For installation on RTD valves with M30X1.5 connecting thread | |||||||
With a gas-filled withdrawal temperature sensor. For installation on RTD valves with M30X1.5 connecting thread |
Copa, Rifar Ventil, Diathherm, Kermi, Korado, Purmo, Rettig, Radson, Demrad, Stelrad |
||||||
With a liquid built-in temperature sensor. To install on valves using a snatching connection |
AXIS VC (with lower liner) |