Menu

Water pipe heating cable. Heating cables for pipe heating. Self-regulating heating cables

House and plot

The heating systems of pipelines for protection against freezing Raychem provide protection against freezing liquids in plastic and metal pipelines, as well as maintenance of appropriate fluidity for oil. This system is nothing but cable heating of pipelines.

To heat pipelines, frostop green cables are used (10 W / m at 5 s) and Frostop Black (18 W / m at 5 s)

Heaters as temperature monitors



Automatically controlled thermostats can be installed directly on the valve using batteries. Here is a special feature that the engine and temperature sensor are connected to the control unit. They control the temperature out through the wireless connection between the temperature sensor and the engine. Instead of an individual temperature regulator on heaters, heating fans or heating fans are also provided as so-called control heaters. These heaters are constantly at the frost, without use for regular heating room.

Under negative temperature ambientThe thermal insulation is not capable of independently protect the pipelines from freezing.

Sigor weather conditions may also lead to blocking fuel lines.

In cold conditions, one heat insulation cannot fully protect the drainage pipes from freezing and to compensate for heat loss, the Raychem heating cable is used, which is one of the main elements of the heating system of the pipeline electrocabel.

Rather, they are used to prevent certain items in the room to the freezing point or to protect against observing a certain ambient temperature. Temperature monitors are installed indoors and have a convective effect, heating ambient air.

Installation of thermal insulation system




Other convective heaters are, for example, pipe heating systems or they do not heat any space, and attached directly to the pipes or in them and controlled by the thermostat. Pipe and heating tapes often pass through aluminum foil tunnels or insulating material so as to withstand heat loss.

Raychem pipe protection systems prevent freezing liquids in plastic and metal pipes.

Most often in winter cold, the risk of water supply controls, both domestic and home, located straight along the street or in a small depth of the ground, increases at different times or in the unheated basement.



Temperature and frost-protective monitors have many tasks both in private and in industrial sectors. They should be used everywhere where objects to be protected are rarely visited, very sensitively react to fluctuations in temperature or in rooms there are no stationary heaters.

Here frosty monitors can prevent cooling rooms and freeze pipes in them.


In the greenhouse, the plant with the frost monitor is sufficiently controlled heat, so they do not freeze. Suitable guardians are autonomous, that is, they are autonomous and with gas or oil powered.

Heat the pipeline

Raychem's heating cables are placed and mounted by straight areas directly on pipes under thermal insulation.

Warming Cable Installation Flexibility

Heating cables can be sliced \u200b\u200bon the plots of the required length in place, which simplifies their installation.

A simple and efficient solution is a cable heating of water supply systems using a self-regulating heating cable. Ultra - modern properties Self-regulation neutralizes overheating by Raychem cables, despite a rather thick layer of thermal insulation. Thanks to this feature, the pipe heating cable will not be abrupting, working a qualitative and reliable period of time.

Installation of a sign for forestry, as well as special tapes for heating pipes, may prevent the freezing of liquids in the pipes and in the worst case to prevent the bloody frost.


In addition, heating ribbons for guide pipes are used to heat the additional channels, for example, like heating of the chute.

In the industrial sector, heaters are used as frosty monitors, so, for example, motor systems remain workable. Thus, a fan with adjustable heating can be used to prevent the freezing of engine oil and other liquids without antifreeze.

Reliability of self-regulatory cables

Heating cables do not overheat even when mounting a mustache. Thus, the system does not require maintenance.



Ease of delivery of heating cables

Raychem heating cables are supplied on a coil (you can order any needed length).

The main tasks of the heating system

For proper use They can provide great help. Here are some tips on how to use them. It has so far been said that frosty monitors are included at a certain temperature. But the guard should also automatically turn off. This feature allows timer or automatic regulation. Frost monitor is turned off when the room temperature is high. This time can be controlled by a timer. For example, you can set the active time for 15 minutes. Then, during this time, the device heats the room, and then turns off until the forest label is reached again.

Manual and description of components

Application area

Protection of pipes from freezing. Maximum external exposure temperature + 65 ° C

  • frostop Green 10 W / m heating cable at 5 ° C and alternative Frostop Black 18 W / m heating cable at 5 ° C

Calculation of the length of heating cable

Heating cable is mounted on the pipe with straight areas. On short taps (up to 3 m), the heating cable is advisable to lay the loop instead of T-shaped branching. The total length of the heated pipe:




Temperature controllers are sensitive to temperature differences that have an appropriate effect on heating behavior. In addition, indoor radiators can easily overheat. You must leave your guard open. Furniture or similar should not be in close proximity. In addition, no object should close the regulator or heater.

Delivery to regions of the Russian Federation - Russian Post

Some manufacturers integrated security setting for this situation: if something is on the frost monitor, it turns off. Others from these devices are automatically disconnected at a certain temperature. Both options are an additional feature of overheating.

  • + about 0.3 m on the supply of food
  • + about 1.0 m on on T-shaped branching
  • + about 1.2 m on branching assembly for 4 chains
  • + about 1 m with additional sources of heat loss (valves more than 2 "and pipe supports without heat exchanging)
  • \u003d total required warmer cable

AT-TS-13 thermostat for cable heating reversal

If this is particularly touching, you must plan more powerful security. Frost plastered machines have an average power of at least 500 W. It can heat around 15-20 square meters space. If you are afraid of too much electricity costs, you can also access gas frost-resistant monitors or oil radiator with freezing protection. Keep in mind that you need power from a wall outlet or batteries for a radio or automatic control unit, regardless of whether you use an electric, gas or oil freezing monitor.

  • Customizable temperature range: - 5 ° C .. + 15 ° C
  • Thermostat with environmental regulation
  • Maximum dial-current current 16 A, 250 V AC
  • JB16-02 - heat-resistant connecting box for supplying power and branching of heating cables
  • CE20-01 - a set for connecting and terminal sealing
  • Hemoft technology.
  • M20 gland.

Selection of thermal insulation to protect pipes and heating cable

Installing the cable inside the pipe

For the manufacture of resistive heating cables, only fluoropolymers are used as insulating material. We have a wide range of heating cables of resistance with fluoropolymer insulation for various applications. Depending on the application, our heating cables are supplied with fluoropolymer insulation or without a protective grid. Parallel heating cables are incredibly versatile in use, as they can be cut from the coil to the desired length, continuing to provide constant power.

Freezing protection for temperatures up to - 20 ° C.

Cables for heating pipelines

Raychem pipeline heating is a freezing protection system, it protects water pipes, fire lines, sprinkler spray systems and fueling from freezing in cold winter conditions. Due to the wide range of applications, the heating cable for pipes is universal for household, industrial and commercial facilities.

Mineral insulation cables are suitable for use with high output requirements up to the highest operating temperatures. High flexibility Low radius curvature High application temperature High chemical resistance resistance to moisture. Since it supports reduced bending radii, it can also be distributed over the entire surface of small parts.

Parallel heating cables are incredibly universal to use, as they can be cut off from the coil to the desired length, continuing to provide constant power. The connecting cable is not needed and can only be supplied on one side. Easy and fast installation allows you to significantly save time and considerable costs.

The heating system of the pipeline from freezing Raychem reduces the total installation and operation costs.

This energy-saving solution includes self-regulating cables and an automatic control device that controls the temperature and includes the system only then in those areas where it is necessary. The heating cable for pipes operates based on a special semiconductor matrix capable of changing its conductive properties depending on the temperature change. That is, it includes the system when the temperature indicators decreases and, on the contrary, turns off it when the indicators reach elevated values.

Mineral insulation insulation cables

Our mineral insulation heating cables are suitable for use in high capacity requirements and the highest use temperatures. Mineral heat-insulating cables are suitable for heating pipes, containers, tank containers, flanges, valves and many other applications.

They can even be installed on concrete floors and walls. Heating cables with mineral insulation have a seamless outer sheath of stainless steel or alloy. They are made entirely of inorganic material, its inner heating element is built into magnesium oxide. Due to the wide range of resistance wires, various cable lengths with different power and operating stresses are possible. Our heating cables are suitable for heating circuits of a short length and several kilometers.

Heating cables to protect against freezing Frostop Green and Frostop Black are suitable for pipes and heating of pipelines from any material (copper, stainless steel, plastic, composite materials or carving pipes) without restrictions. In addition, cable for heating pipelines can be laid both inside the pipe and outside. To select the method of laying, there are certain recommendations with which specially trained specialists are familiar. It is them that it will be advisable to entrust the installation of pipe heating.

Mineral heat-insulating cables are characterized. High performance per meter High applying temperature High chemical resistance Sealed metal case. Extremely durable and mechanically stable. . Our mineral heat-insulating cables are manufactured at the factory and can be supplied on the meter on request. When using heating cables with mineral insulation, it is necessary to ensure a reliable and fully sealed connection. This is guaranteed due to our high-precision laser welding technology.

For plastic pipes It is necessary to use the ATE-180 aluminum fastening tape. Heating cables in freezing protection systems should be closed by fastening ribbon over the entire length of the cable. The thermal conductivity coefficient of thermal insulation λ \u003d 0.035 W / (m k) or below.

Important note: Heating cables to protect against freezing with fluorine by polymer protective sheath (for example, BTV2-CT) should be used for solvent-containing, mixed and / or bitumen thermal insulation. Modern pipe heating systems must necessarily comply with all the above requirements. It is in this case that we can talk about economical, comfortable, reliable and durable work.

Heating cables for pipe heating

For any specific application, contact our engineers. Possessing more than 40 years of experience in the field of electric traction, we recorded our knowledge in a wide variety of industrial applications. Our products are certified and approved for a wide range of applications.

Self-regulating parallel cable, polyolefin insulation

Suitable for dry or wet environments, but not corrosion. Classification area: normal.

Self-regulating parallel cable, fluoropolymer case

It regulates the feed power depending on the temperature of the pipe. Application: Industry and refrigeration equipment.

Selection of thermal insulation. Protection against freezing pipelines for temperatures up to -20



The perfect solution for the cottage, garage, garden plot!

Simple installation and connection.
- Durability and reliability.
- The system of the equation is not required.
- All you need - just turn on the outlet.

Self-regulating parallel cable, insulation and fluoropolymer case

For electrical heating of pipes and tanks while maintaining temperatures when steam cleaning is not performed.

Self-regulating parallel cable, thermoplastic insulation

Self-regulating parallel cable, thermoplastic insulating grid. Application: Industry, Construction and Refrigeration.

Self-regulating parallel cable, insulation and transparent fluoropolymer case

For electrical heating of pipes and tanks while maintaining the temperature when cleaning the ferry. These heaters can be used on objects that need heating, for example, in containers and tanks, fixed in bands with grooves with complex geometric shapes; Immersed directly into the liquid, which is heated or even installed in air ducts for heating air or gases.

A set of heating (heating) cable for heating pipes (pipelines) EBECO frostvakt is used to protect household and industrial water pipelines (plastic and metal, diameter up to 100 mm) from freezing at a negative temperature, indoors and on the street.

You can also use the heating cable for heating the drainage pipes and the funnels (the compound of the heating and conductive cable should not be inside the pipe), drainage systems of air conditioners, soil in greenhouses and telice.

Cable for heating pipes "Pipeline protection" consists of a heating self-regulating EBECO EBTRACE F10 cable, a coherent 2 - 3 m (depending on the power of the kit) with a connecting cable and a detachable compound designed for 220 volt sockets with grounding (Eurovalka). The output thermal power is regulated by the heating element of the cable - a polymer matrix, depending on the heating engineering of the environment. Thus, there is no risk of overheating of the heating cable for leaking pipes and pipelines.

It is used only on heat insulated pipelines, i.e. After laying the heating cable, the pipe or pipe reinforcement (cranes, tees, couplings, flanges, waterproofers, etc.) need to heat insulating. In this case, the heating cable for pipe heating can be coated only by the material withsting the temperature from 65C (for example, a mineral insulation) with a thickness of at least 30 mm.

Heated pipe A self-regulating cable can be carried out by paving the cable both outside the pipe and inside.

Heated pipelines Outside, it is made on newly paved water pipes or on water pipelines, which can be accessed. In this case, the heating cable is fixed on the lower surface of the pipe or wrapped around the pipe around the pipe (depending on the diameter and specific conditions on the object). The cable is attached to the pipe with aluminum tape for heat transfer from the cable evenly, throughout the surface area of \u200b\u200bthe pipe (aluminum scotch, it is necessary to wrap the entire heated area of \u200b\u200bthe pipe). After that, the pipe insulation of the THERMAFLEX type tube insulation is dressed on the pipe, energyflex, etc.

In the absence of access to the pipeline and the inability to ensure it, heating the pipe with self-regulating cable is carried out from the inside of the pipe. At the same time, a tee or a saddle (for all types of plastic pipelines, we recommend that the saddles) are installed in the pipe of the heating cable (for all types of plastic pipelines, we recommend 1/2 "or?". After installing the saddle or drumming the hole in the pipe, the tube box is screwed into the saddelka, in which, according to the supplied instructions, a heating cable is started. ATTENTION! Pipelines with a diameter of 20mm and are heated only outside.